+1 (713) 688-4600 | Sales Toll-Free: (855) SELL BPM | 24/7 Service: +1 (832) 617-5702 info@bpmmicro.com
Select Page

Texas Instruments TMS320F280049PZQR LQFP(100) Device

Adapters for Automated Programmers

9th Gen
LX4ASMR100QFPZS

Adapters for Manual Programmers

9th Gen
LX4ASMR100QFPZS

Adapters for Engineering Programmers


Last Updated: 05/18/2023

If the device is not yet supported by your BPM programmer (Generation), request Device Support

Note


IMPORTANT:

Device Type: TMS320F28004x Piccolo Microcontroller
Device Size: 2KB DCSM OTP + 256KB Flash
Algorithm Programming Method: Parallel GPIO Boot + Custom Bootloader

Memory Organization:

Memory Type

Attributes*

Included in default Range DUT Physical Word Address (hex) BPWin Buffer Byte Address (hex)
User-configurable DCSM OTP Bank 0 R/W No 0007_8000 – 0007_83FF 000F_0000 – 000F_07FF
User-configurable DCSM OTP Bank 1 R/W No 0007_8400 – 0007_87FF 000F_0800 – 000F_0FFF
Flash Bank 0 R/W/E Yes 0008_0000 – 0008_FFFF 0010_0000 – 0011_FFFF
Flash Bank 1 R/W/E Yes 0009_0000 – 0009_FFFF 0012_0000 – 0013_FFFF
Default Algorithm Range 0008_0000 – 0009_FFFF 0010_0000 – 0013_FFFF

*R/W: readable and one time programmable (OTP) R/W/E: readable and rewritable if not locked. Any configurations listed under Device-Specific’ in the menu item Device-> Settings will be written to the DUT during ‘Program’ operation. Special Device Considerations:



1. The OTP and Flash memory sections can be selected via setting the range under Device->Settings.
2. The OTP is not completely blank from the factory. Some bits have already been programmed to 0b0.
3. Each 64-bit word in the OTP can only be modified from the factory default once.
This is because the program operation generates and programs the OTP ECC.
Attempting to reprogram will cause the OTP ECC to be incorrect.
The Link Pointers are excepted since the OTP ECC is not programmed when they are programmed.
4. The Erase operation will blank check the OTP ECC if the OTP section is included
as the OTP ECC will be blank from the factory.
5. The algorithm does not support unlocking the DUT after a password has been programmed.
If the password is programmed all subsequent operations will fail.
6. The BOOTPIN_CONFIG location in the user-configurable DCSM OTP.
If these option is programmed all subsequent operations will fail.

BPM does not sell programmable devices, nor do we program devices directly. BPM makes programmers and accessories to make programming in-house fast, easy, and profitable.

Additional information

Manufacturer

Texas Instruments

Packages

LQFP(100)

Part Number

TMS320F280049PZQR

Set programming

Yes

Vcc(program)

3.3

Package