+1 (713) 688-4600 | Sales Toll-Free: (855) SELL BPM | 24/7 Service: +1 (832) 617-5702 info@bpmmicro.com
Select Page

Smart Modular Technologies SPMAGL1ASI01 (Custom 01) BGA(153) Device

Adapters for Automated Programmers

8th Gen
FVE4ASML153BGL, FVE4ASMC153BGJ, FVE4ASMC153FBGEA, FVE4ASMC153BGZ, FVE4ASM153FBGE (obs.), FVE4ASMC153BGZ, FVE4ASML153BGL, FVE4ASMC153FBGEA, FVE4ASM153FBGE (obs.), FVE4ASMC153BGJ

Adapters for Manual Programmers

8th Gen
FVE4ASML153BGL, FVE4ASMC153BGJ, FVE4ASMC153FBGEA, FVE4ASMC153BGZ, FVE4ASM153FBGE (obs.), FVE4ASMC153BGZ, FVE4ASML153BGL, FVE4ASMC153FBGEA, FVE4ASM153FBGE (obs.), FVE4ASMC153BGJ

Adapters for Engineering Programmers


Last Updated: 05/18/2023

If the device is not yet supported by your BPM programmer (Generation), request Device Support

Note


IMPORTANT: This is a custom algorithm. Please contact BPM before using. Data Buffer Organization:

Data File BPWin Buffer Address (hex)
CID 00_0000_0000 – 00_0000_000F
OCR 00_0000_1000 – 00_0000_1003
CSD 00_0000_2000 – 00_0000_200F
Pre-Enhancement ECSD 00_0000_3000 – 00_0000_31FF
Post-Enhancement ECSD 00_0000_4000 – 00_0000_41FF
Configuration File 00_0000_5000 – 00_0000_5FFF
Firmware File 00_0001_0000 – 00_0008_0BFF
Boot Partition 0 00_0100_0000 – 00_013F_FFFF
Boot Partition 1 00_0140_0000 – 00_017F_FFFF
User Data Area (Pre-Enhancement) 00_0180_0000 – 03_9A7F_FFFF

Special Device Considerations:

1. The algorithm will log the current CID OCR CSD ECSDand Product Information returned by the vendor specific command.
2. All values read from the device will be written to a log file located in your Auto Save Job Summary Report directory.This feature must be enabled otherwise the algorithm will fail.To enable please go to File->Configure and check Enable under Auto Save Job Summary Report.
3. For the CID the algorithm will check against the CID data file.In particular it will check the MID CBX OID PNM and PRV.
4. For the current OCR the algorithm will check against the OCR data file. The entire OCR will be checked.
5. For the current CSD the algorithm will check against the CSD data file.The entire CSD except the checksum and stop bit will be checked.
6. For the pre-enhancement ECSD the algorithm will check against the pre-enhancement ECSD data file.For MLC devices and for the initial pass on pSLC devices the algorithm will check settings related topSLC enhancement to verify they are in the initial state.The algorithm will also check the MAX_PRE_LOADING_DATA_SIZE[21:18] FIRMWARE_VERSION[261:254]PRE_EOL_INFO[267] DEVICE_LIFE_TIME_EST_TYP_A[268] and DEVICE_LIFE_TIME_EST_TYP_B[269].
7. For the post-enhancement ECSD the algorithm will check against the post-enhancement ECSD data file.For MLC devices the algorithm will just check against the pre-enhancement ECSD data file again.
8. The configuration file must list the following fields:Average Erase Count of MLC Average Erase Count of SLC and pSLC.
9. The pSLC conversion setting will read from the pSLC field in the configuration file by default.The pSLC conversion can be explicitly disabled under Device->Settings.
10. After the pSLC conversion the algorithm will check and log the ECSD settingsagainst the post-enhancement ECSD data file.
11. The algorithm will attempt to erase the device (boot partitions and user data area)program the test data loaded in the data buffer verify the data erase the device againand verify that the device is blank.This test will be performed after the pSLC conversion if it is enabled.
12. After the data programming and verification tests the algorithm will repeat the logging forthe various device registers and Product Information.The values used for the ECSD check will change based on the pSLC-related settings.
13. Under Device->Settings it is recommended to reduce the High Device Address based on the end of the test data file.This will reduce the time required for the data programming and verification tests.
14. Under Device->Settings enabling auto range will skip the blank portions of the data bufferused for the data programming and verification tests.However when verifying that the device is blank the full selected range will be used.The Skip blank checking empty Data Pattern regions setting will reduce the range that is verified to be blankto the same range as the initial programming and verification.
15. If using the Field Firmware Update process it must be enabled under Device->Settings.

BPM does not sell programmable devices, nor do we program devices directly. BPM makes programmers and accessories to make programming in-house fast, easy, and profitable.

Additional information

8-bit Bytes

15476981760

Manufacturer

Smart Modular Technologies

Packages

BGA(153)

Part Number

SPMAGL1ASI01

Vcc(program)

3.3