  • Improved the BPWin API to provide users the option to allow BPWin to show message boxes that require operator intervention. By default, the API is aimed to run BPWin unassisted, but this new feature helps users who plan to interact with it in order to resolve arising issues during operation. This feature can be enabled via registry key “ForceToPopupMessageUsingAPI” in the path “BP Microsystems\BPWin\Configuration”.
  • Improved RPI format data parser to support listing optional configurations with no right value assignment. RPI is a format specific to Renesas devices.
  • Improved software by allowing users to customize the maximum runout threshold for Autohandler Systems. This customization can be done via the registry keys “UpperRunoutRange_mils” and “LowerRunoutRange_mils” in the path “BP Microsystems\BPWin\AutoHandler\Components\Pnp\NozzleRunout”.
  • Updated continuity check to improve performance with low voltage devices on all site generations.

Other Updates

  • Fixed an issue on the 3X autohandlers where the laser diagnostics dialog would allow the laser door, elevator, and nozzles to move while the door was open.
  • Fixed an issue happening after placing a device that sticks to the tip of the nozzle for a few milliseconds. In that event, the device was being grabbed again during upward motion due to incorrectly turning the vacuum on too soon. This issue was only affecting 3X autohandler systems with the LNC-120 Cyber Camera.