+1 (713) 263-3776 | Sales Toll-Free: (855) SELL BPM | 24/7 Service: +1 (832) 617-5702

Release Notes on BPWin Software

No Results Found

The page you requested could not be found. Try refining your search, or use the navigation above to locate the post.

7.0.4 Release Notes

Highlights

  • Added a Z self-test motion diagnostic for 4x systems equipped with a Z encoder. This includes some 4900 and all 4910 autohandler systems. This diagnostic executes a sequence of tests to find possible failures and provides recommended actions. Access the Z self-test in the BPWin Motion Diagnostics accessible through the Autohandler menu: Autohandler->Pick-and-Place->Diagnostics. For example, here is a screenshot of the Motion Diagnostics Report where the Z-axis encoder is not connected to the headboard:

  • Improved use of the theta encoder during axis motion to correct failed attempts to arrive at the commanded destination. Added useful debugging log information to help operators pinpoint any hardware faults. In the case of consistent theta failures, the theta speed will decrease incrementally to keep the machine running. This enables operators to finish the current job and address any hardware failures afterward.

Other Updates

  • Added logging information to include the list of selected operations when loading Job Master (.bp) and Automated Job Master (.abp) files.
  • Upgraded the onboard 64GB eMMC memory sticks used in 8th Generation programmers. Customers with 8th Generation programmers that have memory sticks of 32GB can upgrade to this 64GB memory stick. Contact customer support for details. This is part of BPM’s commitment to supporting legacy programmer models in the field.
  • Implemented registry key for administrators to control access to the maximum laser power limit configuration. For further information contact Customer Service.
Download Software

7.0.3 Release Notes

Updates

  • Corrected device placement orientation when automatically removing devices from sockets after sites are taught in sequence. This only occurred when teaching with the options “Full Teach Primary / Fast Teach Secondary”, “Full Teach Every Socket”, or “Fast Validate and Adjust”. This behavior was only present in autohandler systems that use the CyberOptics alignment sensor.
  • Resolved errors when running BPWin in APS simulation mode.
  • Corrected an undesired change in behavior when teaching automated programmer sites in sequence. The correct behavior is to iterate through them in numerical order. Behavior had changed in BPWin 7.0.1 such that the master site was taught first and then the remaining.
  • Improved debugging information given to the operator if:
    • The Z encoder test fails during APS initialization.
    • The SD cards present in the programmer site mismatch expected serial numbers.
  • Resolved a problem where a JobMaster file could not be saved when Custom37 Bad Block Management scheme was selected.

Device Support Update

Device Name Programmer Criticality Changes Made & Reasons Socket Module
Macronix MX66U51235FXDI-10G 2800/3800/3800-MK2/4800 Critical The algorithm has been updated to resolve reading and verifying issues. FVE4ASM24BGB, FVE4ASMC24BGJ
Atmel ATSAMD20J18A-AU 2610/3610/4610 Recommended Algorithm has been updated to support all non-reserved bits in the user row. ASMR64TQFP

7.0.2 Release Notes

Highlights

  • Improved the BPWin API to provide users the option to allow BPWin to show message boxes that require operator intervention. By default, the API is aimed to run BPWin unassisted, but this new feature helps users who plan to interact with it in order to resolve arising issues during operation. This feature can be enabled via registry key “ForceToPopupMessageUsingAPI” in the path “BP Microsystems\BPWin\Configuration”.
  • Improved RPI format data parser to support listing optional configurations with no right value assignment. RPI is a format specific to Renesas devices.
  • Improved software by allowing users to customize the maximum runout threshold for Autohandler Systems. This customization can be done via the registry keys “UpperRunoutRange_mils” and “LowerRunoutRange_mils” in the path “BP Microsystems\BPWin\AutoHandler\Components\Pnp\NozzleRunout”.
  • Updated continuity check to improve performance with low voltage devices on all site generations.

Other Updates

  • Fixed an issue on the 3X autohandlers where the laser diagnostics dialog would allow the laser door, elevator, and nozzles to move while the door was open.
  • Fixed an issue happening after placing a device that sticks to the tip of the nozzle for a few milliseconds. In that event, the device was being grabbed again during upward motion due to incorrectly turning the vacuum on too soon. This issue was only affecting 3X autohandler systems with the LNC-120 Cyber Camera.